Emergency & Clinics Apparatus

AggRAM Automatic Platelet Aggregometer

Brand: NL Diagnostica·Ships from Brazil
Price on request

Send a free RFQ and get the supplier's best price.

Min Order1 Unit
ConditionNew
WarrantyYES
Country of shippingBrazil
Save Share

Request for quotation

Free · No obligation · Supplier replies on WhatsApp

Trade with confidence on Abraa

Safe and secure payments using Abraa safe trade systems

Learn more

Supplier verification not completed

Pay only through Abraa to stay protected. Never pay a supplier by direct transfer.

Learn more

Secure Payment

Pay through Abraa, never by direct transfer to a supplier.

Product Inspection

Book a check before shipping to confirm quality and quantity.

Buyer Protection

Get support and refunds if goods arrive not as described.

Verified Suppliers

Licence, address and on-site checks by the Abraa team.

Product Specification

Brand NL Diagnostica
Condition New
Warranty YES

Product Descriptions

The AggRAM is an automatic platelet aggregometer with operating in a Windows environment, flexible software with automatic calculation of the curve (Slope) with cofactor quality control ristocetin (Westgard, Levy Jennings, log, integration) .You can operate in conjunction with another Total of 8 channels on the same computer. With laser beam reading technology, it offers stability and excellent performance, while reducing costs.

• TYPES OF TESTS: Platelet Aggregation and Ristocetin Cofactor;
• ABSORBANCE: Operates with laser beams to ensure greater sensitivity;
• OPTICAL MEASUREMENT CHANNELS: 4 channels of optical measurement, individual or combined, and can be increased to up to 8 channels;
• CUBETAS: 8 x 60 mm (siliconized glass);
• MAGNETIC BARS: 3.5 X 4 mm (for magnetic stirring);
• INCUBATION AND MEASUREMENT TEMPERATURES: 37 ° C + -1 ° C;
• GRAPHICS: -20% to 110% of activity (+/- 0.5%) versus time;
• OPERATIONAL TEMPERATURE: Between 15º C and 30º C;
• VOLTAGE: 110/220 V, 50/60 Hz, 1200 Watts Maximum;
• DIMENSIONS: 15 cm height x 25 cm width x 43 cm length;
• QUALITY CONTROL: Levy Jennings Curve and Westgard Rules. It has control for optical calibration and, if necessary, performs the automatic adjustment of the laser beams.
• OPERATING SYSTEM: Microsoft Windows 2000, Monitor: Super VGA (800 x 600), Keyboard and mouse, The inkjet printer.
• MANUFACTURER: Helena Laboratories.

Reagents for Platelet Aggregation
• ADP;
• Epinephrine;
• Collagen;
• Arachidonic acid;
• Ristocetin;
• Ristocetin Cofactor.
No Feedbacks yet.
Please login to review this product.
close image\
Product Added To Container Successfuly !
An error occured while adding the product
please try again later !
You can't order less than 1
Welcome to Abraa !
Subscribe now to receive the Abraa Newsletter with latest products, best offers and current deals directly to your email !
Loading…