Product Specification
| Brand | EVERYWAY |
| Condition | New |
Product Descriptions
The interferential stimulator (IF) device is a battery operated device that includes two controllable output channels. Amplitude, mode and duration of the electrical impulses can be altered with the buttons or knobs. The controls are protected by a cover in order to prevent accidental changes to the settings. Slide the cover down to make adjustments to the controls.
|
|
MECHANISM |
TECHICAL DESCRIPTION |
|
01 |
Channel |
Dual, isolated between channels |
|
02 |
Dimensions |
107x62x27mm |
|
03 |
Weight |
Approximately 150 grams, battery included |
|
04 |
Amplitude |
Adjustable 0-60mA peak into 500 ohm load each channel,constant current |
|
05 |
Carrier Frequency | 4000Hz, Fixed (CH1) |
|
06 |
Modulating Frequency | 4-160bps, Adjustable (CH2) |
|
07 |
IF Frequency Modes | 9 modes, 1 constant mode, 5 frequency shift modes, 3 auto sweep Modes |
|
08 |
Constant Mode | 4-160bps, Adjustable |
|
09 |
Auto Sweep |
4-45 bps |
|
10 |
Frequency Shift |
Five modes, |
|
11 |
Sweep Time | 15 seconds |
|
12 |
Frequency Shift |
Frequency shifts from 30% below the set frequency to 60% above and then return to 30% below the set frequency. |
|
13 |
Output Configuration | Quad polar (4 electrodes) |
|
14 |
Wave form | Symmetrical Balanced Sine Wave |
|
15 |
Interference |
4-160 bps, Adjustable, 4 bps/step |
|
16 |
Pulse Duration | 125 µs maximum |
|
17 |
Patient Compliance Meter | Display total treatment time |
| 18 | Lock | Prevents the patient from accidentally changing any of the set parameters |
| 19 | Timer | 15, 30 minute selectable |
| 20 | LCD | Displays mode, bps rate, abrupt/ramp, timer, and channels |
| 21 |
Max charge per |
15 Micro-coulombs Maximum |
| 22 | Low Battery | A low battery indicator will show when the battery is low. |
| 23 | Power Source | 9 Volt DC adapter, 500mA or 9 volt alkaline battery (not recommend due its short life) |
| 24 | Tolerance | There may be +/-10% tolerance of settings and 20% tolerance of output. |
\