LINZ-8B Micro Syringe Pump
Send a free RFQ and get the supplier's best price.
Trade with confidence on Abraa
Safe and secure payments using Abraa safe trade systems
Supplier verification not completed
Pay only through Abraa to stay protected. Never pay a supplier by direct transfer.
Secure Payment
Pay through Abraa, never by direct transfer to a supplier.
Product Inspection
Book a check before shipping to confirm quality and quantity.
Buyer Protection
Get support and refunds if goods arrive not as described.
Verified Suppliers
Licence, address and on-site checks by the Abraa team.
Product Specification
| Brand | Shanghai LEIEN |
| Condition | New |
Product Descriptions
Basic Parameter
Model: LINZ-8B
Dimensions (mm): 271(L)×167(W)×287(H)
Weight: 3.6kg
Built-in batteries: DC 12V 2800mAh
Battery Continuous Use Time: About 4 hours for single channel
(fully charged new battery running with rate 5ml/h)
Rated Consumption: ≤42 VA
Power supply: AC 100V~AC 242V、50/60HZ(±1 HZ)
Battery Model:Ni-MH, rechargeable
Syringe Size: 10/12ml, 20/25ml, 30/35ml,50/60ml
Infusion Flow Selection: 0.1ml/h~1600ml/h, original value is 0.1ml/h
Bolus rate:Syringe 50ml:1600ml/h
Syringe 30ml:900 ml/h
Syringe 20ml:600 ml/h
Syringe 10ml:400 ml/h
Infusion Range:0.1ml~9999.9ml, original value is 0.1ml
Flow Rate Precision: ±3%
KVO: 0.1ml/h
Occlusion Pressure: High:110kPa±20kPa (825mmHg±150 mmHg)
Middle:80kPa±30kPa (600mmHg±225mmHg)
Low:60kPa±20kPa (450mmHg±150 mmHg)
The biggest output pressure < 975mmHg(130kPa)
Use Environment:Temperature: 5℃~43℃
Relative Humidity:≤90%RH (Under without condensation status)
Atmospheric Pressure:860hPa~1060hPa
Storage Environment:Temperature:-20℃~+55℃
Relative Humidity:≤90%RH (Under without condensation status)
Atmospheric Pressure:860hPa~1060hPa
Waterproof Level: IPX4
Electric Shock Protection: Class I, Type CF
Alarm: occlusion, nearly finish, finish, standby (no operation) low battery, battery exhausted etc.
Function: transfusion amount display, flow rate display, infused volume display etc.
Special Function
KVO (Keep Vein Open):After finish setting infusion amount, for prevent to form thrombus, keep to infusion at
the lowest rate 0.1ml/h.
Power Switching Function:When AC power is disconnected, automatically switch into battery power supply
and give indication. When the AC power is connected, automatically switch into
AC power working.
Repeat Alarm Function: If the alarm real reason is not be resolved within 2 minutes after press “SILENCE”
button, it will give alarm again to remind to resolve the problem.
Data Memory Function: Able to save the latest setting alarm volume level, brand, occlusion pressure level for
use next time. Able to save for five years.
BatteryProtection Alarm: For protect battery and safety infusion, the battery power will be displayed as
different levels in sound and light from nearly finish to exhausted.
Move alarm: When try to move or take the syringe away, it will give alarm.
\