Product Specification
BERICA CAVI | |
New | |
YES |
Product Descriptions
APPLICATION: Suitable for use in home appliances with high heat development and in industrial environments at high and low temperature.
INSTALLATION: For fixed installation within equipment.
FEATURES | DESCRIPTION | STANDARDS |
---|---|---|
Conductors: | annealed red or tinned copper cl.5 | CEI EN 60228 (Tabella 9) |
Insulation: | silicone rubber | |
Insulation colour: | on request | |
Flame retardant: | CEI EN 60332-1-2 | |
Halogen free: | (< 0,5 mg/g - 0,5%) | CEI EN 50267-2-1/2 - IEC 60754-1/2 |
DC resistance: | according to | CEI EN 60228 (Tabella 9) |
Rated voltage Uo/U: | 300/500 V | |
Max voltage: | 550 V | |
Testing voltage: | 2000 V | |
Max working temperature: | 180 °C | |
Short-circuit temperature: | 350 °C | |
Min. installation temperature: | -40 °C | |
Bending radius: | Ø x 3 | |